5
Copyright© 2009, 2014 Corbin Russwin, Inc., an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Corbin Russwin, Inc. is prohibited.
Technical Features
ML20700 x PWI1 Mortise Lock
Technical Data
Power Supply: 6 AA alkaline batteries
Voltage (max/min): 9 VDC / 5.5 VDC
Expected Battery Life: 1-3 years based on usage
Card Track: Track 2
Card Coercivity HiCo (4000 Oersted)
Features
Operating Modes PIN required: Specify KM, IKMPS, or CKMP; In addition to card, a 4 digit PIN might be required
No PIN required: Specify MA, IMPS, CMP; Only card is required
Passage Modes Automatic: The door automatically becomes unlocked during any passage mode
Manual: The door only becomes unlocked after the rst card of the day is presented (within a schedule) or might
optionally be configured to require two consecutive swipes to toggle the passage state
Inside/Outside Escutcheons
• Keys/buttons overmolded to prevent wear
• Zinc die cast
• Tactile keypad
• LED’s indicate valid/invalid entries
• Escutcheon projection 1-11/16” (43mm)
• Operating temperature: 32°F to 104°F (inside)
• Operating temperature: -4°F to 104°F (outside -
heating element optional for card reader)
• Humidity: <95% non-condensing
• Storage temperature: -22°F (-30°C) to
176°F (80°C)
Monitoring
ML20700 x PWI1 Request to Exit (REX); Latchbolt (LX); Dead Bolt (DX); Auxiliary Latchbolt (AX)
Outside shown
3-1/16"
(78mm)
11-5/8"
(295mm)
3-1/16"
(78mm)
11-3/16"
(284mm)
Inside shown