access control
accessories
ELECTROMECH
LOCKS
..MAGLOCK
SECURITRON.COM
Windstorm-Rated, Preload-Handling
Electromechanical Strike
The universal electromechanical UNL strike works with
most North American cylindrical locksets, with or without
deadlatches. The UNL supports full deadlatch function,
releases under pressure and includes latch status monitoring.
Strong enough to withstand windstorm conditions, the
UNL provides Grade 1 holding power and is UL listed and
fire-rated. Like all Securitron locks, the UNL is backed by
Securitron MagnaCare—the industry’s best lifetime,
no fault replacement warranty.
UNL
UnLatch
®
Strike
product options
• 12VDC
• 24VDC
• FSUNLforeld-selectable
fail-safe operation
product features
• Nocuttingoralteringofthe
jambrequired
• Releasesunderpreload
• Supportsdeadlatchfunction
• FitsstandardANSI4-7/8”
strike cutout
• Motordrivenaction
• Latchstatussensor
included (SPDT)
• MagnaCareLifetime
Replacement No Fault Warranty
FSUNL-12
Fail Safe/Fail
SecureUnLatch
Module,12VDC,
.90mA
FSUNL-24
Fail Safe/Fail
SecureUnLatch
Module,24VDC,
1.4mA
UNL-12
UnLatchfor
CylindricalLocks,
12VDC
UNL-12-10B
UnLatch12VDC,Oil
Rubbed Bronze
UNL-12-US3
UnLatch12VDC,
Polished Brass
UNL-24
UnLatchfor
CylindricalLocks,
24VDC
UNL-24-10B
UnLatch24VDC,Oil
Rubbed Bronze
UNL-24-US3
UnLatch24VDC,
Polished Brass
Part #
Description
modeLs
Current Draw:
12VDC:40mA
continuous,minimum
300mA when operating
24VDC:40mA
continuous,minimum
200mA when operating
Operating
Temperature:
-20 to +125F
[-29 to +52C]
Shipping Weight:
6lbs[2.72kg]
Finishes:
USD/ –
Stainless Steel
USB/ –
Oil Rubbed Bronze
US/ –
Polished Brass
Specications:
• UL10CListed,3hour
single door
• CAN4-S104-80m
Listed,3hour
single door
• ULlistedtoANSI/
SDI-BHMA A250.13 (60
PSI) Windstorm
• ANSI/BHMAA156.31,
Grade1;E09321,
E09322,E09323
• NFPA-252redoor
compliant
• ASTM-E152redoor
compliant
• Patentnumbers:
5,474,342;6,022,056
1.33”
[33mm]
3.375”
[86mm]
1.5”
[38mm]
BPS-12-1 or BPS-24-1 with battery backup or a 3 Amp/1.5 Amp 12/24VDC
power supply output recommended for startup inrush to achieve best
operation when used in preload conditions